Skip to content

Evidence centre

Every report in full. With number, date and conditions.

We do not publish excerpts or screenshots. You download the complete document and see who tested what, and under which conditions.

Documents
7
Institutes in Poland
3
Latest
06.2025 · PZH
Hospital study
ICU · TÜV NORD

Reports and documents

  • AirIBPRS-PIB · Łódź, Poland

    Airborne microbe reduction, set of 3 luminaires 3000K

    Room of 9 m², 2.9 m high. MAS-100 ECO air sampler 1 m above the floor. Measurements after 5 min, 60 min, 6 h and 24 h.

    Result

    Total microbial count −92.41%, moulds and yeasts −85.28% after 24 h

    No.: K/508/02/2024
    Date: 13.01.2025

    Full report (PDF)
  • AirIBPRS-PIB · Łódź, Poland

    Airborne microbe reduction, set of 3 luminaires 6000K

    Room of 9 m², 2.9 m high. MAS-100 ECO air sampler 1 m above the floor. Measurements after 5 min, 60 min, 6 h and 24 h.

    Result

    Total microbial count −92.48%, moulds and yeasts −85.57% after 24 h

    No.: K/508/01/2024
    Date: 30.12.2024

    Full report (PDF)
  • Air · hospitalTÜV NORD · Thailand

    Air quality in a surgical intensive care unit

    Pathum Thani Hospital, 14th floor. NIOSH 0800 method. Measurements before switch-on and after 1, 3, 6 and 24 h.

    Result

    Bacteria 245 → 34 CFU/m³ (−86%), fungi 264 → 26 CFU/m³ (−90%) after 24 h

    Percentages calculated from the counts given in the report.

    No.: 2404979
    Date: 24.05.2024

    Report on request
  • AirAStar Laboratory · Malaysia

    Airborne microbe reduction, 1 luminaire

    Non-sterile store room at the laboratory, 24°C, 60% humidity. NIOSH 0800 method.

    Result

    Bacteria −92.73% after 6 h and −94.55% after 24 h, fungi −89.13% after 24 h

    No.: JB/ASL/M2203/0409-0415
    Date: 26.03.2022

    Full report (PDF)
  • SurfacesUgene Laboratory · Singapore

    Bacteria reduction on stainless steel surfaces

    Steel discs 60 cm from 5 luminaires, 23°C. With reference to BS EN 17272 and ASTM E3135.

    Result

    S. aureus −99.71%, E. coli −99.67% after 6 h

    No.: 49732-52779/23
    Date: 08.01.2024

    Full report (PDF)
  • SafetyCIOP-PIB · Warsaw

    Nanoparticle emission when cleaning the luminaire

    EVLN-SDL-24W(S) 6000K, 3 samples. Dry and wet cleaning in a test chamber, SMPS analyser.

    Result

    518–654 particles/cm³ against a reference threshold of 20,000. No significant nanoparticle release.

    No.: 287/PZ/2025/NC
    Date: 05.05.2025

    Full report (PDF)
  • ApprovalsNIPH NIH-NRI (PZH) · Warsaw

    Hygiene certificate for EVLN T8, DL, PL and SDL luminaires

    Residential and public buildings, including healthcare facilities (excluding rooms with elevated hygiene requirements), food industry production and storage.

    Result

    The product meets hygiene requirements. Valid until 17 June 2030.

    No.: B.BK.60112.0440.2024
    Date: 17.06.2025

    Full report (PDF)

Questions procurement teams ask

Does EV SUN light contain UV?

No. The luminaires emit in the 450–600 nm range and are in the photobiological exempt group (RG0) under IEC 62471. Microbe reduction is triggered by ordinary white light, thanks to the copper in the nano-coating.

Does the luminaire only work right next to it?

No. It works throughout the room, not just near the luminaire, in the air and on surfaces. In the IBPRS-PIB test the sampler stood 1 m above the floor and the luminaires were on the ceiling at 2.9 m.

Does the coating release nanoparticles?

Not to any significant extent. CIOP-PIB measured emissions during dry and wet cleaning of the luminaire: 518–654 particles/cm³ against a reference threshold of 20,000 (report 287/PZ/2025/NC).

Can they be installed in hospitals?

Yes. PZH hygiene certificate B.BK.60112.0440.2024 covers healthcare facilities, excluding rooms with elevated hygiene requirements such as operating theatres.

Why does the effect grow over time?

Air circulates in the room and gradually passes the luminaires. In the IBPRS-PIB test the reduction was 34% after 6 hours and 92% after 24 hours, so the luminaires work best in continuous operation.

Need documents for a tender?

Datasheets, CE declarations and the PZH certificate in one place.

Downloads →